Frequently Asked Questions

39 questions answered by our engineering team, covering materials, specifications, certifications, and ordering.

Antigen Extraction Tube with Split Dropper Tip

View Product →
What is the difference between Type A, B and C tube bodies?▼
They are three tube body sizes for different swab heads and buffer volumes. Tell us your swab and buffer volume and we match the body to your kit.
Does the dropper tip ship already fitted to the tube?▼
Dropper tips ship as a separate component, 10,000 sets per carton, so your kit line can fit them after filling. Pre-filled tubes come with the tip in place.
Can the same tube body take a tethered cap?▼
Yes. Type A, B and C bodies fit both the split dropper tip and the tethered cap used on our self-test extraction tube.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

Self-Test Extraction Tube with Tethered Cap

View Product →
Why use a tethered cap for a self-test kit?▼
The cap stays joined to the tube, so a home user has one part to handle instead of a loose cap and a loose dropper.
Which tube bodies does the tethered cap fit?▼
It fits tube bodies Type A, B and C, the same bodies used with our split dropper tip.
Can you supply swabs for a home-test kit?▼
Yes. Nylon flocked sampling swabs are available as an accessory, so the tube and swab come from one supplier.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

0.3 mL and 0.5 mL Micro Extraction Tubes

View Product →
When should I use a micro extraction tube?▼
Use it when your test needs only a small amount of buffer, so the swab stays immersed without diluting the sample.
How is the 0.5 mL micro tube packed?▼
The 0.5 mL single-ear micro tube ships 10,000 per carton. Packing for the 0.3 mL tube is set with your order.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

Double-Ended Extraction Tube

View Product →
What kits use a double-ended extraction tube?▼
Kits that add a second reagent after the first extraction step, or that keep the swab and buffer apart until the test starts.
What do you need from us to quote a double-ended tube?▼
Your test steps, the liquids and their volumes, and the swab you use. A sample of your current tube helps us match the format.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

Extraction Tube for Rapid Test Analyzers

View Product →
How do you match the tube to our analyzer?▼
We work from your analyzer model and a sample of the tube it takes, matching length, diameter and cap to the instrument.
Can analyzer tubes come pre-filled?▼
Yes. We fill them with your buffer at your fill volume and pack them for your kit.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

Buffer Dropper Bottles

View Product →
What volumes do the dropper bottles hold?▼
Five models cover buffer volumes from 50 µL to 2000 µL. Tell us your fill volume and we pick the bottle that fits.
How are dropper bottles packed?▼
They ship 2,000 per bag, with 40,000 per carton for the 50–1000 µL models and 20,000 per carton for the 50–2000 µL model.
Is there a single-dose alternative?▼
Yes. BFS buffer vials hold one sealed dose of buffer per test, from 200 µL to 3000 µL.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

BFS Buffer Vials

View Product →
What fill volumes are available in BFS vials?▼
Nine models cover ranges from 200–500 µL up to 500–3000 µL. Tell us your target fill and we match the vial.
How are BFS vials packed?▼
BFS buffer vials ship 10,000 per carton.
Can you fill the vials with our buffer?▼
Yes. Send us your buffer formulation and fill volume, and we deliver filled, sealed vials ready for your kit. Empty vials are also available.

5 mL FOB Stool Extraction Tube

View Product →
What is the difference between the screw cap and flip cap?▼
Both carry the grooved sampling rod. Choose the one that matches how your users open and close the tube.
Can this tube hold a 30–60 mL stool sample?▼
This tube is a 5 mL extraction tube for FOB rapid tests. Larger stool sample cups are a separate product.
How are the stool tubes packed?▼
They ship 200 per bag and 5,000 per carton.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

Funnel Saliva Collection Extraction Tube

View Product →
What comes in each saliva collection set?▼
A funnel, an extraction tube and a cap.
Can the tube be pre-filled with buffer?▼
Yes. We fill the tube with your buffer so the saliva mixes into it as soon as it is collected.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

Swab Lysis and VTM Sample Tube

View Product →
What is the difference between VTM and lysis buffer tubes?▼
VTM keeps the sample intact for transport and later testing. Lysis buffer breaks open the sample so nucleic acid testing can start straight from the tube.
Can you supply swabs with the VTM tubes?▼
Yes. Nylon flocked sampling swabs are available as an accessory.
Can you fill our buffer into this product?▼
Yes. Send us your buffer formulation and fill volume, and we deliver it filled, capped and packed for your kit. Empty bulk supply is also available.

DNA and RNA Spin Column with Collection Tube

View Product →
Do the columns come with collection tubes?▼
Yes. Each spin column is supplied with a collection tube for the flow-through.
Can one column format serve DNA and RNA kits?▼
Yes. A silica membrane binds DNA or RNA depending on the binding, wash and elution buffers your kit uses.
How are spin columns supplied?▼
In bulk packs for kit makers who assemble and label their own kits. Tell us your pack count per kit and we pack to fit your line.

50 mL QuEChERS Extraction Tube and 15 mL PSA C18 Purification Tube

View Product →
What is in the 15 mL cleanup tube?▼
PSA and C18 sorbents for dispersive SPE cleanup of the extract from the 50 mL tube.
Can you pack salts and sorbents to our method?▼
Yes. Tell us the method and amounts, and we pack each tube to match.

Get Samples Matched to Your Kit

Send us your test type, swab and buffer volume. We reply with matching tubes and bottles and send free samples for your evaluation.

View our privacy policy.

© 2026 ExtractionTube | All rights reserved.